TECHNICAL SPECIFICATIONS CIRCUIT BREAKER TANK DEAD 24kVITEMFEATURESUNITSREQUESTEDOFFERED1Type of circuit breaker required Dead tank - VacuumDead tank - Vacuum2Installation Site Outdoor, 1000 meters above sea levelOutdoor, 1000 meters above sea level3Number of poles 334Rated operating voltagekV13.8245Rated operating voltagekV24246Dielectric rigidity to atmospheric impulses at sea levelKVpk1251257Dielectric rigidity at industrial frequency at sea levelkV50658Minimum leakage distance of the insulationmm5006009Nominal frecuencyHz606010Rated currentA2000200011Nominal line interruption currentA161012Rated short circuit interruption capacity a) Effective value of the alternating componentkArms2525 b) Effective value of the continuous component%324913Opening factor of the first pole 11.514Rate for increasing the recovery voltage to 100% of the interruption capacitykV/µs0.811.0515Nominal short-circuit capacitykA658016Nominal sequence of operation 0-0,3s-CO-15s-CO0-0,3s-CO-180s-CO17Nominal short circuit durations1418Nominal interruption capacity in phase mismatchkA57.919Maximum total interruption timems506020Maximum dead time for high speed reclosingms10010021Adjustment range for reclosingms33030022Mechanism of operation (closing and firing) motor - springmotor - spring23Mechanical endurance class M2M224Control voltage / motor voltage 12522025Insulators material PorcelainPorcelain26Connector suitable for copper cable per pole:kcmil250 - 800MCM250 - 800MCM27Local control panel 27.1Degree of protection IP55IP5527.2Equipped with heating controlled by humidity detector (YES / NO) YESYES27.3Interior lighting (YES / NO), control by door switch YESYES27.4Opening and closing controls, electrical and mechanical YESYES27.5Terminals for signal acquisition for the SCADA system YESYES28As it is of the dead tank type, it should be included in the supply of the same types of bushings current transformers, the one for protection (25VA 5P20) and the other for measurement (25VA Cl. 0.2)The ratio of the current transformers must be multirrelation 2000/5 ANSI C57.13 standard for which you must attach the catalog and respective plans. TECHNICAL SPECIFICATIONS CIRCUIT BREAKER TANK DEAD 24kVITEMFEATURESUNITSREQUESTEDOFFERED1Type of circuit breaker required Dead tank - VacuumDead tank - Vacuum2Installation Site Outdoor, 1000 meters above sea levelOutdoor, 1000 meters above sea level3Number of poles 334Rated operating voltagekV13.8245Rated operating voltagekV24246Dielectric rigidity to atmospheric impulses at sea levelKVpk1251257Dielectric rigidity at industrial frequency at sea levelkV50658Minimum leakage distance of the insulationmm5006009Nominal frecuencyHz606010Rated currentA2000200011Nominal line interruption currentA161012Rated short circuit interruption capacity a) Effective value of the alternating componentkArms2525 b) Effective value of the continuous component%324913Opening factor of the first pole 11.514Rate for increasing the recovery voltage to 100% of the interruption capacitykV/µs0.811.0515Nominal short-circuit capacitykA658016Nominal sequence of operation 0-0,3s-CO-15s-CO0-0,3s-CO-180s-CO17Nominal short circuit durations1418Nominal interruption capacity in phase mismatchkA57.919Maximum total interruption timems506020Maximum dead time for high speed reclosingms10010021Adjustment range for reclosingms33030022Mechanism of operation (closing and firing) motor - springmotor - spring23Mechanical endurance class M2M224Control voltage / motor voltage 12522025Insulators material PorcelainPorcelain26Connector suitable for copper cable per pole:kcmil250 - 800MCM250 - 800MCM27Local control panel 27.1Degree of protection IP55IP5527.2Equipped with heating controlled by humidity detector (YES / NO) YESYES27.3Interior lighting (YES / NO), control by door switch YESYES27.4Opening and closing controls, electrical and mechanical YESYES27.5Terminals for signal acquisition for the SCADA system YESYES28As it is of the dead tank type, it should be included in the supply of the same types of bushings current transformers, the one for protection (25VA 5P20) and the other for measurement (25VA Cl. 0.2)The ratio of the current transformers must be multirrelation 2000/5 ANSI C57.13 standard for which you must attach the catalog and respective plans./* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
Related products about 24kv Dead Tank Vacuum Circuit Breaker for Substation
-
Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
-
Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
-
Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
-
Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
-
G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
-
New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
-
China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
-
Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup